How do I get SeeMore images into my Electronic Medical Record (EMR) or PACS (Picture Archiving and Storage System)?
|
|
Answer
|
Most EMR’s and PACS have an “Import File” function you can use to import JPGs into the system. Patient information and results of calculations are displayed on JPG image. You can also copy patient information and calculation information from the text files within the patient folder, and paste them into the EMR. These files have extensions .pat and .clc respectively. An HL7 bridge to Centricity EMR is available from a 3rd party. |
| Back to top |
|
|
Can I run SeeMore USB software on a Mac?
|
|
Answer
|
You can run SeeMore USB software on a Mac. Here are the requirements: You need to install software to create a dual boot, such as: Fusion or VMWare, plus you will need a copy of Windows. See this website for more information: http://www.apple.com/macosx/compatibility/ |
| Back to top |
|
|
Where can I find out about ultrasound training and other clinical updates?
|
|
Answer
|
Ultrasound training is available at most Medical Schools and from a number of private groups. See our "Resources" page for a listing of training organizations. Another good source for upcoming courses is: www.sonoworld.com |
| Back to top |
|
|
Where can I get ultrasound gel?
|
|
Answer
|
One source is Parker Labs: http://www.parkerlabs.com/ultrasound_products.html
You can Google "ultrasound gel" for other sources.
|
| Back to top |
|
|
Do you support M-Mode or fetal heart rate monitoring?
|
|
Answer
|
No, SeeMore only supports real-time imaging. |
| Back to top |
|
|
Do you have Doppler or color flow?
|
|
Answer
|
No, SeeMore is imaging only. |
| Back to top |
|
|
Do you comply with HIPPA guidelines?
|
|
Answer
|
Interson SeeMore software does not include electronic signature control, and is not meant to substitute for an electronic medical record. Ultrasound images, patient data files, and reports may include identifying patient information. HIPAA regulations and other patient privacy and regulatory standards require that users take reasonable care to protect this information. It is important that you comply with your own hospital or clinic HIPAA guidelines regarding privacy and safeguarding patient information. |
| Back to top |
|
|
How do I return probe for service?
|
|
Answer
|
You must first call or email Interson office to get an RMA (Return Merchandise Authorization number). |
| Back to top |
|
|
Are probes waterproof? Can they be submerged or soaked?
|
|
Answer
|
Probe may be soaked up to probe connector. Best not to soak more than one hour. |
| Back to top |
|
|
How do I clean probes?
|
|
Answer
|
Use wipes or solution you normally use for cleaning instruments. Transeptic cleaning solution is available from Parker Labs http://www.parkerlabs.com/transeptic.html
A probe cover/sterile drape must be used with endocavity probes. These are available from Civco and Parker medical and other suppliers. Probe must not be autoclaved. |
| Back to top |
|
|
Where can I get biopsy guides and probe covers?
|
|
Answer
|
Biopsy Guides and probe covers for EB probe are available from Civco http://www.civco.com/mmi/ultrasound_products/guidance/endocavityguides/chison/610-1091/
Guides accommodate BARD Biopty gun |
| Back to top |
|
|
Is a cart available?
|
|
Answer
|
Interson does not sell carts, but you can purchase a cart from Versatable Fusion Cart – about $300
http://www.versatables.com/pages/products/spacesaver/lts0503.php |
| Back to top |
|
|
How do I make measurements?
|
|
Answer
|
Go to the Measure tab . Establish first point with a right click on computer, and drag cursor. Release to place the second cursor. Note that measurements can also be performed on saved images. For annotation, position cursor, right click, type word in, then hit ENTER key on computer keyboard to set – hit clear to cancel. |
| Back to top |
|
|
What does the button on the probe do?
|
|
Answer
|
The button performs two functions: It is the orientation button (corresponds to the asterisk on the right side of the screen. It is usually pointed either to the patient’s head or the patient’s right side; and you may freeze or unfreeze images with the button. |
| Back to top |
|
|
What does the “Missing Folder Error Message” mean?
|
|
Answer
|
If you get error messages about missing folders, you are probably encountering a VISTA security problem. For VISTA systems, you must install SeeMore Setup software as “administrator.” To do so, right click on installation program, and chose: “run as administrator.” You need only do this once. |
| Back to top |
|
|
How do I get clinician name and facility name into the system?
|
|
Answer
|
Go to the preferences tab. You may enter as many facility/practice name, and physician names as you like. You can then choose from pull-down pick list. |
| Back to top |
|
|
Which probe should I use for each application?
|
|
Answer
|
For Abdominal Imaging: AB 3.5 MHz
For OB: AB 3.5 MHz
For Bladder Scanning: AB 3.5 MHz
For FAST exam: AB 3.5 MHz
For AAA screening: AB 3.5 MHz
For Vascular Access: VA 7.5 MHz probe
For Transrectal Prostate imaging: EB 7.5 MHz
For Transvaginal Imaging: EB 7.5 MHz: |
| Back to top |
|
|
How do I viewed saved images?
|
|
Answer
|
Static (still) images are stored as both .JPG and .bs (high res) files – the latter can only be viewed via the SeeMore software via the “Load” feature. JPG files (found within Patient Folders) can be viewed with any image editing software by clicking on the file. Cine loops may only be viewed via the SeeMore software using the “Load Images” button under the Cine section. |
| Back to top |
|
|
How do I print hardcopy of images?
|
|
Answer
|
Although many users chose to store images digitally rather than print them out, you can print directly from the SeeMore application by selecting File (upper left of screen), then Print, using a standard printer connected to your computer. You can also right click on the .jpg images within SeeMore Data file, Patient Folder, and select the print function. Because there is so much black space, it is suggested that you print a smaller image rather than full page in order to conserve ink. You may also connect a USB thermal printer to your printer. |
| Back to top |
|
|
Do you save images in Dicom format?
|
|
Answer
|
We do not. However, there are several inexpensive software products that will convert JPG images into Dicom images. See: http://www.tims.com or http://www.Sorna.com. |
| Back to top |
|
|
Can SeeMore probes run on a MAC?
|
|
Answer
|
Yes, if Mac is running dual boot, Windows Operating System. |
| Back to top |
|
|
How do I install a new version of software?
|
|
Answer
|
You do not need to remove the old version of software, but make sure it old version is closed when installing new version. |
| Back to top |
|
|
What do I do if I get a “No Probe Recognized” message?
|
|
Answer
|
Before launching SeeMore software, plug in probe into USB port. You should hear two short beeps, which means the system has recognized the probe. Then launch SeeMore software. Note: Make sure software installed before probe is initially plugged in. Next, make sure drivers are loaded. This can take a little time, and you must wait until two sets are loaded. |
| Back to top |
|
|
What do I do if image is not displaying properly on my screen?
|
|
Answer
|
Make sure probe plugged in first, before launching software.
Make sure cable firmly seated in back of probe. Sometimes, user may accidentally have two copies of SeeMore running at once. This can cause unpredictable results. Using Control/Tab combination, you can see what applications are running on your computer. If you see more than one SeeMore logo, it means you have multiple copies running. Shut them both down and start again.
Display resolution and color depth are set within the Display control within Windows Control Panel. The software will not load or display correctly unless these settings are correct. If in doubt, check these settings before loading software. Screen resolution needs to be set at 32 bit color and set at 96 DPI = normal screen. If you’re seeing a bunch of squiggly lines instead of image, Right click on the desktop, select Properties, go to Settings, click Advanced, and select "Normal size" (96 DPI – dots per inch).
|
| Back to top |
|
|
How do I tell which version of SeeMore software I am running?
|
|
Answer
|
Go to the “Help” menu on the top left of the screen and pull down “About SeeMore”. You will see version number listed. |
| Back to top |
|
|
What are the minimum system requirements to run SeeMore USB probes?
|
|
Answer
|
* Computer Operating System – Windows 7, XP, or Vista, 32 or 64 bit
* Minimum processor – 1 GHz
* Minimum RAM – -Recommend 1 GB or more
* USB 2.0 port * Minimum Display – 1024 x600 resolution with 32 bit color
* Mac – must run Windows OS as dual boot |
| Back to top |
| If you do not find an answer to your question here, please email us, and we will respond promptly. |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |